Technical Specifications; Scope Of Delivery; Dimensions; Installation Example - Franke AQRM653 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6.

Technical Specifications

Minimum flow pressure:
Recommended flow pressure:
Maximum operating pressure:
Calculation flow rate:
Volumetric flow:
Flow duration at 38 °C:
7.

Scope of Delivery

Quantity
1
1
2
1
1
4
1
8.

Dimensions

9.

Installation Example

10. Jet Dispersion

11. Assembly Instructions

Warning!
Use the fitting only with non-return valves and the grit filters specified.
Failure to observe can result in an increased bacterial load in drinking water and
cause a health risk or even risk of death.
Important!
Before installing, flush the pipes in compliance with DIN 1988.
To protect the tiles, use masking tape when marking and drilling. Drill at low speed.
1.0 bar
1-5 bar
10 bar
0.20 l/s at a flow pressure of 3 bar
1–50 s adjustable with shower head 0.20 l/s)
Description
Stainless-steel casing with:
Self-closing single mixer, blockable water flow regulators,
connecting hoses and AQUAJET Slimline shower head
only AQRM683, AQUA712: automatic shower-pipe
evacuation
Connection bracket
Hook-in strip
Flow rate regulator 0.15 l /s
Screws, dowels
Installation and Operating Instructions
0,15 l/s
0,15 l/s
- 5 -