10.10 Optional: Connect the second sensor.
i ... Adapter line for sensors
k ... Door contactor
l ... yellow
m ... brown
10.11 Optional: Connect the third sensor.
i ... Adapter line for sensors
n ... Release for handicapped users
o ... white
p ... green (use in conjunction with 2/3 Y-sensor junction, core colour "yellow")
10.12 Hook-in the cover plate (r) on to the top of the tongues in the frame and attach.
10.13 Use the screws (s) to fix the cover plate at the bottom.
11. Function
Triggering water flow
11.1 Press the Piezo-button.
• Water flows.
• Water flow stops automatically after the set flow duration time has passed.
Flow duration
The flow duration has been factory-set to 10 s. The flow duration can be altered in
steps of 0.1 seconds, from 1 – 6500 s.
12. Adjusting the Flow Duration
Flow duration can be adjusted with a free program available from Franke.
13. Setting Hygiene Flushing
Hygiene flushing can be adjusted with a free program available from Franke.
14. Maintenance and Servicing
Depending on the quality of the water, the local conditions and the rules and regula-
tions applicable on site, the fitting must be maintained and serviced at regular
intervals.
Use suitable cleaning agents that are not harmful to the fittings in a proper manner
and rinse with water after use. High-pressure cleaners must not be used for
cleaning.
7