Off time
This function allows the user to set the
backlight on time during which the display
remains lit after the last command given
(default value 30 seconds).
Language
The user may select the display language:
Italian, English, French, German, Spanish
Exit
To return to the settings menu.
Sensor menu
Use the
(DOWN) or
Sensor
This function selects the sensor type:
•
2-wire standard sensor (STD)
•
3-wire electronic sensor (HAL)
Barbotin
The circumference of the gypsy must be
entered in this row (in centimeters or inches).
To enter the correct value see the paragraph
"instrument calibration"
Divisor
If the standard 2-wire electronic sensor
(STD) is used, this value must be left at 1. If
the 3-wire electronic sensor is used, the
divider must be set equal to the number of
gypsy teeth. See paragraph "Instrument
calibration".
WHC040
Select with
Select value with
Confirm with
Select with
Select value with
Confirm with
Confirm with
SENSOR
SENSORE
BARBOTIN
DIVISOR
TEST
EXIT
(UP) key to move around the parameters.
Select with
Select value with
Confirm with
Select with
Select value with
Confirm with
Select with
Select value with
Confirm with
STD
33.0
1
25
English
Rev. 02-2021