UK
Fault
The appliance turns on,
but the temperature is
too high/low
The appliance is
leaking water
The appliance is
unusually loud
Technical Specifications
Model
Voltage
Power Current
G619
220-240V
180W
G211
50Hz
CB507
220-240V
180W
DP288
50Hz
CB509
220-240V
375W
DP289
50Hz
6
CB507-CB509-G619-G211-DP288-DP289_ML_A5_v18_20190109.indb 6
Probable Cause
Too much ice on the evaporator
Condenser blocked with dust
Doors are not shut properly
Appliance is located near a
heat source or air flow to the
condenser is being interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being
stored in the appliance
Appliance is overloaded
The appliance is not properly
levelled
The discharge outlet is blocked
Movement of water to the drain is
obstructed
The water container is damaged
Loose nut/screw
The appliance has not been
installed in a level or stable
position
Temperature
Range
1.2A
2°C to 12°C
1.2A
2°C to 12°C
2.3A
2°C to 12°C
Solution
Defrost the appliance
Call POLAR agent or qualified Technician
Check doors are shut and seals are not
damaged
Move the refrigerator to a more suitable
location
Increase ventilation or move appliance to a
cooler position
Remove any excessive hot foodstuffs or
blockages to the fan
Reduce the amount of food stored in the
appliance
Adjust the screw feet to level the appliance
(if applicable)
Clear the discharge outlet
Clear the floor of the appliance (if
applicable)
Call POLAR agent or qualified Technician
Check and tighten all nuts and screws
Check installation position and change if
necessary
Capacity
Dimensions
Refrigerant
(litres)
H x W x D mm
68
R600a 40g
885 x 428 x 386
86
R600a 40g
980 x 425 x 425
235
R290 90g
1690 x 515 x 485
Weight
(kg)
33.2
36.5
76.4
2019/1/9 14:47