UK
Fault
The appliance is
The frame has become loose
unusually loud
The appliance has not been
installed in a level or stable
position
Electrical Wiring
POLAR appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as
standard.
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:
•
Live wire (coloured brown) to terminal marked L
•
Neutral wire (coloured blue) to terminal marked N
•
Earth wire (coloured green/yellow) to terminal marked E
All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
Technical Specifications
Model
Voltage
Power
G619
230V
130W
G211
50Hz
CB507
230V
130W
DP288
50Hz
CB509
230V
250W
DP289
50Hz
Disposal
EU regulations require refrigeration products to be disposed of by specialist companies who remove or
recycle all gasses, metal and plastic components.
Consult your local waste collection authority regarding disposal of your appliance. Local authorities are not
obliged to dispose of commercial refrigeration equipment but may be able to offer advice on how to dispose
of the equipment locally.
Alternatively call the POLAR helpline for details of national disposal companies within the EU.
5
Probable Cause
Temperature
Current
Range
0.9A
0°C to 12°C
0.9A
0°C to 12°C
1.5A
0°C to 12°C
Check and tighten all nuts and screws
Check installation position and change if necessary
Capacity
Refrigerant
(litres)
70
R134a 70g
86
R134a 83g
235
R134a 180g
Action
Dimensions
H x W x D (mm)
885 x 428 x 386
980 x 428 x 429
1695 x 515 x 485
Weight
(kg)
32.5
36,5
76.4