ENGLISH
User manual translated from the
these user instructions cover R01 series units
(see nameplate).
CONTENTS
.......................................................................................Page
OPERATING FUNCTIONS ..............................................................................7
D-PRO AUTOMATIC 2.2 kW SCHEMATIC DIAGRAM .....................................8
D-PRO AUTOMATIC 2.2 kW MOTHERBOARD ...............................................9
D-PRO AUTOMATIC 2.2 kW FRONT BOARD ...............................................10
GENERAL SAFETY PRECAUTIONS
D-PRO Automatic door control units are conforming with established safety
legislation, as are the contents of this manual. Incorrect installation can result
in serious injury to the installers and users. For this reason, during installation,
always strictly observe all instructions in this manual.
Do not proceed with the installation if anything is unclear to you; contact
Nice customer service for support.
WORK SAFELY!
CAUTION! - These instructions are critical to your safety.
CAUTION! - Keep the important safety instructions.
Observe the following instructions in full:
• Only make the electrical hookup specified in this manual; improper
hookup can serious damage the system.
• If used outdoors, the cables must be completely protected by plastic
cable ducting.
Given the risks attendant on the installation and use of the system, the
propulsion system installation must satisfy the following requirements:
- only make the modifications given in these instructions to the control unit and
drive. Any other modifications may result in damage. The manufacturer is not
liable for damage caused by arbitrary modifications to the propulsion system
or control unit;
German
- make sure the control units are out of the reach of sources of heat and open
flames at all times. Failure to do so may result in damage, fire and other hazards;
- do not immerse the control unit or drive in water or other fluids during their
installation. Do not allow fluids to enter the system during the installation;
- the propulsion system's packaging must be disposed of in accordance with
local regulations.
CAUTION! - Keep these instructions carefully as a reference for scrapping and
servicing the equipment.
BASIC DESCRIPTION AND PREPARING THE
INSTALLATION
Description and use
The D-PRO Automatic is a control unit for three-phase and single-phase drives
for sectional, rapid and roller doors, running on 230 and 400V power, with
mechanical or electronic limit switches. It is compatible with all usual safety and
control devices.
Other possible applications (traffic lights, inductive loops for recognising
vehicles or remote service functions) can be implemented by inserting other
boards (modules).
To open or close a door, simply press the button on the housing or the
corresponding external button.
In automatic mode, the door can be also be opened closed by radio.
Any other use is non-conforming! The manufacturer is not responsible
for damage resulting from non-conforming use of the system's
equipment not specified in these instructions.
The manufacturer is responsible for the entire system and must ensure
observance of the applicable standards and directives (including EN 13241-
1). The manufacturer must ensure that the EMC, Low Voltage, Machinery and
Construction Products directives are observed.
He is responsible for providing the technical documentation for the system as a
whole, which must be enclosed with the system itself.
National and local regulations governing the installation must be
observed, as well as any national accident prevention legislation.
When working on the installation, the door system must be disconnected from
its power supply.
Pre-installation controls
Before starting the installation of the control unit, carefully read these installation
and user instructions in full.
The manufacturer is not liable for any responsibility or guarantee relating to the
product if the system is modified without his written authorisation in advance,
or non-conforming installations in violation of the installation instructions are
done or permitted.
The manufacturer must ensure that the EMC, Low Voltage, Machinery and
Construction Products directives are observed.
CAUTION! - The control unit and drive may not be used in potentially
explosive environments.