Name/Value
b5...b6: Reserved
b7: AC control max
b8: AC control min
b9...b14: Reserved
b15: Grid current
130.04
Limit word 4
b0...b1: Reserved
b2: I max user
b3: Iout Temperature
b4: MV Station limit
b5...b6: Reserved
b7: Nominal power
b8...b15: Reserved
130.05
Limit word 5
b0: Idc CS temperature
b1: Idc PS temperature
b2: Idc IGBT
temperature
b3: Idc LCL
temperature
b4: Idc ambient
temperature
b5: Power section 1
b6: Power section 2
b7: Power section 3
b8: Power section 4
b9...b15: Reserved
130.06
Limit word 6
b0: Iout CS temperature
b1: Iout PS temperature
b2: Iout IGBT
temperature
b3: Iout LCL
temperature
b4: Iout ambient
temperature
b5...b15: Reserved
130.11
Active power limit to
grid
-
130.13
Reactive power limit
Description
Affichage de l'état des limitations en fonction du courant.
Paramètre en lecture seule.
Affichage de l'état des limitations du courant d'entrée en
fonction de la température.
Paramètre en lecture seule.
Affichage de l'état des limitations du courant réseau en
fonction de la température.
Paramètre en lecture seule.
Affichage de la puissance active maxi admissible fournie
au réseau.
Paramètre en lecture seule.
Affichage de la puissance réactive maxi admissible
fournie au réseau.
Paramètre en lecture seule.
Description des paramètres 81
Préréglage/
EqBT16/32
0x0000/
Liste de bits
0x0000/
Liste de bits
0x0000/
Liste de bits
-/
Valeur réelle
1 = 1 kW
-/
Valeur réelle

Publicité