Description Of The Instrument - sylvac ULD4 1000 Mode D'emploi

Règle digitale
Table des Matières

Publicité

1. Description of the instrument

1
1. Beam fixing point
2. Moving means
3. Electronic module (see 681.279.05)
4. Side fixing position
5. Top fixing position
6. Main beam
2. Specifications
Instrument
Measuring range (A)
External dimension (C)
Nb. holes row
Max error.
Repeatability
Weight
Max. speed of travel
Measurement system
Working temperature (storage)
Electromagnetic compatibiliy
IP rating (according with
IEC60549)
Coefficient of expansion
2
3
MINMAX
1
2
mm
IN
H
B
B
TOL
PRESET
INPUT
x
ULD4
ULD4
1000
1500
0-1120mm
0-1620mm
1306mm
1806mm
3
4
60 µm
90 µm
20 µm (with constant measuring force)
1.2
1.5
Sylvac Inductive System (patented)
+5 to +40° C (-10 to +45° C)
electronic module : IP67
3
4
5
ULD4
ULD4
2000
2500
0-2120mm
0-2620mm
2306mm
2806mm
5
6
120 µm
150 µm
1.8
2.2
2.0 m/s
as per. EN 61326-1
Steel 11.5um/°C/m
E
6
ULD4
3000
0-3120mm
3306mm
7
200 µm
2.5