Fig. 2: Premium Line 190/300/600
Available spare parts: Please refer to www.aqua-medic.de.
The O-ring for sealing the membrane housing must be slid onto the membrane housing before
screwing the cap on.
4. Maintenance
-
Flushing: In order to flush the membrane, only the flushing valve has to be opened. Then, the water
flows with high speed through the narrow channels in the membrane and takes most of the residuals
with it. This flushing also cleans the flushing valve itself.
After 15 - 20 minutes, the valve must be closed again. A minimum water flow (approx. 12 – 20 / 15 -
24 l/h) has to be guaranteed.
1. Water inlet
2. Pure water connection
3. Flushing valve
4. Cap of module housing
5. Reverse osmosis module
incl. membrane
6. Pre-filter housing for fine
filter
7. Pre-filter housing for
activated carbon filter
8. O-rings
9. Flat gasket
10. Fine filter element
11. Activated carbon filter
element
12. Holding clip for module's
housing
13. Mounting bracket
8