To access the Parameters setting mode proceed as follows:
press, for at least 3 seconds, the Ip button;
•
•
press first the
button then press together the
When the function is activated, the display shows "F01" with the value of the selected parameter.
parameters setting
•
Press +/-
buttons for scrolling parameters;
•
Press +/-
buttons to change the single parameter value;
note: the value is automatic saved after about 3 seconds.
(Do not press any button as long as the value does not flash again).
Description of parameter
F01
Type of gas boiler
10 = sealed chamber - 0 = atmospheric chamber
F0
Type of gas
00 = natural (metane) - 01 = LPG
F03
Hydraulic system
00 = instantaneous appliance
05 = appliance with external water tank
08 = only heating appliance
F04
Programmable relay 1 setting
= zone system (See Service instructions)
F05
Programmable relay 2 setting
13 = Cool function (See Service instructions)
F06
External sensor programmable input setting
(See Service instructions)
F07...F09
Manufacture information
Remote control installation
F10
00 = wall mounting (section 7.2)
01 = not used
0 = boiler front panel (section 7.1)
F11...F1
Manufacture information
F13
CH max. heating output
F14
D.H.W. max. heating output (0-100%)
F15
CH min. heating output
F16
Maximum temperature setpoint setting
00 = 85°C - 01 = 45°C
F17
Pump overrun time
(01-40 minutes)
F18
Minimum burner pause
in central heating mode (01-10 minutes) - 00=10 seconds
F19
Manufacture information
F0
Manufacture information
F1
Anti-legionella function
00 = Disabled - 01 = Enabled
F
Manufacture information
F3
Maximum D.H.W. setpoint
F4
Manufacture information
F5
Lack of water safety device
F6...F9
Manufacture information (only read parameters)
F30
Manufacture information
F31
Manufacture information
F3...F41
Diagnostics (See Service instructions)
last
Controller stop function activation (See Service instructions)
parameter
00 = Disabled - 01 = Enabled
WarnInG:
do not modify the values of the "Manufacture information" parameters.
InstructIons pertaInInG to tHe Installer
19. parameters setting
button.
(0-100%)
(0-100%)
37
Default value
310 Fi
10
00 o 01
00
02
04
00
00
00
00
100
100
00
00
03
03
07
00
00
00
60
35
00
--
10
30
--
00
1.310 Fi
08
95.188.3 - GB