Based on 30 p.s.i. / 2.11 bar safety valve setting
Vessel charge and initial system pressure
Total water content of system using 2.2 gal / 10 l
capacity expansion vessel
supplied with appliance
For systems having a larger capacity MULTIPLY the TOTAL system capacity in litres (gallons) by
the factor to obtain the TOTAL MINIMUM expansion vessel capacity required in litres (gallons)
note: When the boiler is operating at maximum operating temperature, providing heating with all radiators operating, the
pressure gauge should not indicate more than 25.5 p.s.i. / 1.8 bar. If the reading exceeds this figure an additional expan-
sion vessel is required.
central Heating Mode (Fig. 1)
1. With a demand for heating, the pump circulates water through the primary circuit. At a pre-determined flow rate the
central heating flow switch operates, initiating the ignition sequence.
. The main burner ignites at low rate, then the gas valve controls the gas rate to maintain the heating temperature mea-
sured by the temperature sensor.
3. When the flow temperature exceeds the setting temperature, a 3 minute delay occurs before the burner relights auto-
matically (anti-cycling). The pump continues to run during this period.
4. When the demand is satisfied the burner is extinguished and the pump continues to run for a period of 3 minutes (Pump
Overrun).
Key
1
Primary Heat Exchanger
2
Burner
3
Ignition Electrode
4
Flame Sensing Electrode
5
Gas Valve
6
Pump
7
Automatic Air Vent
8
Expansion Vessel
9
Plate Heat Exchanger
10
Flow Sensor with Filter
11
Boiler Drain Point
12
Pressure Relief Valve
13
Heating Return
14
Cold Water Inlet On/Off Valve and Filter
15
Gas Inlet
16
Domestic Hot Water Outlet
17
Heating Flow
18
Automatic By-Pass
19
Water Pressure Switch
20
Manometer
21
Domestic Hot Water Temperature Sensor
22
Three Way Valve
23
Three Way Valve Motor
24
Safety Thermostat
25
Central Heating Temperature Sensor
Fig. 1
InstructIons pertaInInG to tHe Installer
2.8 system volume
2.9 boiler schematic
central Heating circuit
7
bar
0.5
psi
7.25
Litres
120
(Can)
gal
26.4
(USA)
gal
31.7
0.0833
1.0
1.5
14.5
21.7
91
64
20
14
24
16.9
0.109
0.156