Concentric pipes (ø 80/125)
The boiler has been designed to be connected to concentric outlet/
suction pipes and with the opening for air suction closed. The concen-
tric outlets can be placed in the most suitable direction according to room
requirements, complying with the maximum lengths indicated in the table.
For installation, follow the instructions supplied with the kit. To go
through the wall, drill a hole of Ø 140 mm. According to the length
of the pipes used, it is necessary to insert a flange selecting from
those contained in the boiler (see table). Pay special attention to
external temperature and pipe length. Refer to the diagrams in order
to establish if it is compulsory or not to use a condensation collector.
In case of operation at temperature lower than 60 °C, it is compulsory
to use a condensation collector. If a condensation collector is used,
provide a slope of the flue exhaust pipe of 1% towards the collector.
Connect the condensation trap syphon to a white water outlet pipe.
Non insulated outlet pipes are potential sources of danger.
24 C.S.I.
Pipe length
Ø 80 125 [m]
from 0,96 to 3,85
from 3,85 to 7,85
from 7,85 to 12,4
(**) fitted in boiler
TWIN OUTLETS (ø 80) (fig. 11)
Twin outlets can be placed in the most suitable direction according
to the room requirements.
To use the combustion air suction pipe, one of the two inlets (G and
H) must be selected. Remove the closure plug which is fixed using
screws, and use the specific adaptor relating to the inlet selected.
The air inlet adaptor ø 80 (X) must be correctly oriented, it is
therefore necessary to fix it using the appropriate screws, so
that the locating tab does not interfere with the casing: X air
inlet adaptor ø 80 - Y air inlet adaptor from ø 60 to ø 80.
When necessary, the flue gas flange (F) must be removed using
a screwdriver as a lever. The table indicates the permitted linear
lengths. According to the length of the pipes used, it is necessary
to insert a flange, selecting one from those contained in the boiler
(see the following table).
The maximum lengths of individual pipes are shown in the graphs
(fig. 11).
24 C.S.I.
Pipe length
ø 80 [m]
2+2
>2+2 ÷ 6+6
>6+6 ÷ 16+16
(**) fitted in boiler
B22P/B52P Suction indoors and discharge outdoors
C12-C12x Discharge via concentric wall outlet. The pipes may leave the
boiler independently, but the outlets must be concentric or sufficiently
close together to be subjected to similar wind conditions (within 50 cm)
C22 Discharge via concentric outlet in common smoke pipe (suction and
discharge in the same pipe)
C32-C32x Discharge via concentric roof outlet. Outlets as for C12
C42-C42x Discharge and suction in common separate smoke pipes, but
subjected to similar wind conditions
C52-C52x Separate discharge and suction lines on wall or roof and in
areas with different pressures. The discharge and suction lines must
never be positioned on opposite walls
C62-C62x Discharge and suction lines using pipes marketed and certi-
fied separately (1856/1)
C82-C82x Discharge via single or common smoke pipe and wall suction line
C92-C92x Discharge on roof (similar to C32) and air suction from a sin-
gle existing smoke pipe
Load losses for each
Flue gas
bend (m)
flange (F)
45°
Ø 42
(**)
1,35
Ø 44
not installed
Load losses for each
Flue gas
bend (m)
flange (F)
45°
Ø 42
1,2
(**)
Ø 44
not installed
MAXIMUM LENGTH OF CONCENTRIC PIPES
90°
To direct the outlets in the most suit-
2,2
able installation way (right air input)
there is an air/flue gas splitter kit
available.
reduced concentric bend kit
If it is necessary to install Quadra on existing systems (replace-
ment of Ciao N/Ciao range), there is a "reduced concentric bend"
kit that allows boiler positioning while keeping the same flue
gas hole.
Pipe length with
reduced bend [m]
up to 1.85
from 1.85 to 4.25
90°
1,7
COMPULSORY
CONDENSATE BASIN
NON-COMPULSORY CON-
OUTSIDE TEMPERATURE (°C)
Flue gas flange (F)
Ø 44
no flange
C32
C32
C52
C42
C82
C22
C22
C42
C12
C52
QUADRA II 24 C.S.I.
Ø 80/125
DENSATE BASIN
air/flue gas
splitter
Load losses for
each bend (m)
90°
45°
1.5
1
B22P
B52P
C12
5