7 Additional Functions

7.1 Key lock
A key lock may be activated as a protection
against unauthorized change of adjustments.
With activated lock, adjustments can only be
made after the input of a special key sequence.
1) Press the button MENU repeatedly until the
highest menu level is reached (in fig. 2 on the
very left).
2) Press the button UP or DOWN repeatedly
until the display shows
3) Press the button ENTER. The display shows
(key lock off).
4) Use the button UP or DOWN to switch to
As soon as the display is extinguished, the
key lock is activated.
5) To be able to make adjustments now:
a) When the display does not light up, first
press any button.
b) Press the button ENTER. The display will
be extinguished.
c) Then press the following buttons:
UP, DOWN, UP, DOWN.
Each time one of these buttons is
pressed, the display shows an asterisk ( ).
d) To finish press the button ENTER. The
display shows the last menu item
selected. As long as the display is illumi-
nated, adjustments can be made. When it
is extinguished, the key lock is reacti-
vated.

7.2 White balance

The spotlight is factory-set so that a certain white
shade is created at maximum brightness of the
colours red, green and blue. This white shade
may also be adjusted warmer or colder, e. g. to
balance differences to other spotlights when
these spotlights are controlled together with the
ODP-1210RGBW.
1) Press the button MENU repeatedly until the
highest menu level is reached (in fig. 2 on the
very left).
2) Press the button UP or DOWN repeatedly
until the display shows
3) Press the button ENTER. The display now
shows
.
4) Press the button ENTER again. The display
now shows ,
or
000 and 255.
= brightness of red
= brightness of green
= brightness of blue
5) Select the three adjusting functions succes-
sively with the button ENTER and adjust the
brightness in each case with the button UP or
DOWN so that the desired shade of white
results.
6) Activate the adjusted shade of white:
a) Press the button MENU repeatedly until
the display shows
14
7) To be able to control the spotlight by DMX, go
.
.

7.3 Slow response of the LEDs

LEDs respond immediately to a change of the
brightness adjustment. To simulate the slow
response of standard lamps, the response can
be adjusted in 4 steps. For the 11-channel mode
channel 10 (chapter 6.3.5). For the 3-channel,
4-channel, 5-channel and 6-channel modes
make the adjustment as follows:
1) Press the button MENU repeatedly until the
2) Press the button UP or DOWN repeatedly
3) Press the button ENTER. The display shows
4) If
5) Press the button ENTER. The display shows
.
6) To be able to control the spotlight by DMX, go
and a number between
again.
All rights reserved by MONACOR
manual may be reproduced in any form or by any means for any commercial use.
b) Press the button DOWN twice so that the
display shows
.
c) Press the button ENTER. The display
shows
,
,
,
d) If
is not shown, press the button UP
or DOWN as many times as necessary.
e) Press the button ENTER. When the dis-
play shows
, the adjusted shade of
white is activated. When it shows
switch to
with the button UP or DOWN.
from the menu branch
to the menu item
:
a) Press the button MENU repeatedly until
the display shows
again.
b) Press the button UP or DOWN repeatedly
until the display shows
c) Press the button ENTER. The display
shortly shows the DMX start address. If
DMX control signals are received now, a
point must flash on the display.
this adjustment is made via the DMX
highest menu level is reached (in fig. 2 on the
very left).
until the display shows
.
,
,
,
or
is not shown, press the button UP or
DOWN as many times as necessary.
the present adjustment:
immediate response
slightly slow response
...
response as slow as possible
Select the desired adjustment with the button
UP or DOWN.
from the menu branch
to the menu item
:
a) Press the button MENU repeatedly until
the display shows
again.
b) Press the button UP or DOWN repeatedly
until the display shows
c) Press the button ENTER. The display
shortly shows the DMX start address. If
DMX control signals are received now, a
point flashes on the display.
7.4 Resetting the spotlight
to the factory settings
The spotlight is factory-set as follows:
or
.
Function
colour spotlight
show programs
,
adjustment for the
master / slave mode
DMX start address
number of DMX channels
subaddress
function subaddress
.
function white balance
slow LED response
11 shades of white
white balance
key lock
To reset the spotlight to the factory settings:
1) Press the button MENU repeatedly until the
highest menu level is reached.
2) Press the button UP or DOWN repeatedly
until the display shows
3) Press the button ENTER. The display will
change to
4) If
is not shown, press the button UP or
DOWN as many times as required.
5) Press the button ENTER. The display will be
extinguished. Then press the following but-
tons:
UP, DOWN, UP, DOWN.
.
Each time one of these buttons is pressed,
the display shows an asterisk ( ).
Press the button ENTER to start the reset.
6) Then switch back to
MENU. Select the operating mode with the
button UP or DOWN and activate it with the
button ENTER.
8 Specifications
Data protocol: . . . . . . . . . DMX 512
Number of
DMX channels: . . . . . . . . selectable:
Light source : . . . . . . . . . 12 RGBW LEDs
Power per LED . . . . . . 8 W
.
Beam angle . . . . . . . . 25°
Power supply: . . . . . . . . . 230 V/ 50 Hz
Power consumption: . . . . max. 120 VA
Protective class
of housing: . . . . . . . . . . . IP 67
Dimensions: . . . . . . . . . . ∅ 230 mm × 210 mm
Weight: . . . . . . . . . . . . . . 5.8 kg
Subject to technical modifications.
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction
Factory setting
R = 255, G = 255,
B = 255, W = 030,
S = 00
AT.01
slave unit
001
= 11 channels
01
off
off
off
factory-set values
R = 255, G = 255,
B = 255
off
.
,
,
,
or
.
with the button
3, 4, 5, 6 or 11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

38.3140

Table des Matières