Possible Causes - Efco DS 3000 D Manuel D'utilisation Et D'entretien

Unité motrice
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
GB
WARNING: Always stop unit and disconnect spark plug before performing all of the
recommended remedies below except remedies that require operation of the unit.
When all the possible causes have been checked and the problem is not resolved, consult an
Authorised Service Centre. If a problem occurs that is not listed in this table, consult an Authorised
Service Centre.
PROBLEM
Engine will not start or will
run only a few seconds
after starting.
Engine starts but will not
accelerate properly or will
not run properly at high
speed.
Engine does not reach full
speed and / or emits
excessive smoke
Engine starts, runs and
accelerates but will not
idle.
WARNING: Do not attempt to carry out repairs without the necessary repairs and
technical expertise. Poorly executed repairs will automatically invalidate the warranty and
relieve the manufacturer of all liability.
26
13. TROUBLESHOOTING

POSSIBLE CAUSES

1. No spark
2. Flooded engine.
Carburetor
requires
adjustment.
1. Check oil fuel mixture.
2. Air filter dirty.
3. Carburetor requires
adjustment.
Carburetor
requires
adjustment.
SOLUTION
1. Watch for spark at spark plug
tip. If there is no spark, repeat
test with a new spark plug
(CMR7A).
2. Follow procedure page 19. If
engine still fails to start, repeat
procedure with a new spark
plug.
Contact a Servicing Dealer for
carburetor adjustment.
1. Use fresh fuel and the correct
2-cycle oil mix.
2. Clean
per
instruction
Maintenance-Air Filter Section.
3. Contact a Servicing Dealer for
carburetor adjustment.
Turn idle speed screw "T"
(Fig. 9) clockwise to increase idle
speed. See Operation-Carburetor
Adjustment.
in

Publicité

Table des Matières
loading