Mounting Instructions - Marmitek AWM2 Guide Utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
Red: input 2, second address
When the red wire is connected to the blue wire, the programmed
"address +1" will be transmitted (e.g. when A3 is programmed as the
base address then the Marmitek X-10 address A4 will be sent by using
input 2). If the status in the MicroModule was ON, an OFF command
will be transmitted. If the status in the MicroModule was OFF, an
ON command will be transmitted. Through this transmission, other
Marmitek X-10 modules can be switched remotely over the power
line or Macro's setup in the computer interface can be activated.

Mounting instructions

WARNING! ALWAYS SWITCH OFF THE MAIN MASTER SWITCH
BEFORE INSTALLING THE MICROMOdULE.
To install the MicroModule AWM2 the following wiring is required.
1. Neutral
2. Phase 230v
3. load. This wire runs directly to the load.
Take the present switch (if one is installed) out of the wall outlet
box.
disconnect all wires from the switch.
Pull an additional Neutral-wire in case this one is missing.
8
Figure 1
© MARMiTeK

Publicité

Table des Matières
loading

Table des Matières