RZ_HLSG_2015_Mehrsprachig.qxp_Text_GB HLSG 30.06.16 08:30 Seite 18
4
Technical data
General
High-performance sprayers: 405 T, 405 TK, 405 TKS, 505 T, 505 TK, 410 T, 410 TI, 410 TK, 410 TKS, 510 T,
510 TK
Permissible positive operating pressure: 6 bar / Permissible operating temperature: 0°C to +50°C /
Full pressure change (0-6 bar) for max. 5000 load changes / Spray pipe holder / Pressure relief
valve / Pressure gauge / Flat spray nozzle: 80° / Max. output: 1 l/min / Reaction force on the noz-
zle: < 5 N / Pump material: brass / Mesh size of filter in quick closure valve: 0.9 mm / Residual
quantity following horizontal emptying: none
Individual
High-performance sprayers 405 T
Max. filling capacity in litres
Total container content in litres 8
Empty weight in kg
Compressor connection
Backrest
Oil-resistant device
Container material:
- Steel, internally coated
- Stainless steel
Special accessories: see figure on page 2; further accessories at www.gloriagarten.de
5
Assembly
5.1
5 litre device >>
5.2
10 litre device >>
6
Commissioning
WARNING
CAUTION
ing components may result in draining or spouting of spraying agent. You should therefore
observe the following safety instructions:
Prior to each use, check the device to ensure fault-free condition and leak-tightness.
To perform the leak test, fill the container with water!
Inspect all screw joints for tight fitting.
6.1
5/10 litre devices >>
figures
405 TK
405 TKS 505 T
5
5
5
5
8
8
8
4,4
4,4
4,5
4,35
-
x
x
-
-
-
-
-
x
x
x
x
x
x
x
-
-
-
-
x
–
figures
1
–
figures
5
Before putting into operation, observe Chapter 2 "For your safety".
Danger to health due to escaping spraying agents! A leaking device or leak-
6.1.1 Inspecting the safety valve
–
10
11
505 TK
410 T
410 TI
410 TK
5
10
10
10
8
13,7
13,7
13,7
4,35
5,6
5,6
7,0
x
-
-
x
-
x
x
x
x
x
-
x
-
x
x
x
x
-
-
-
4
9
18
410 TKS 510 T
510 TK
10
10
10
13,7
13,7
13,7
5,7
5,5
7,0
x
-
x
x
x
x
x
x
x
x
-
-
-
x
x