5.8.6 - Service

This screen allows to set many and important parameters on which depend the heat pump operation.
Access is governed by password, (installer, service and factory) which allows access to a part
or all of the parameters.
By means of the arrows "UP" and "DOWN" it is possible to scroll the list and value
of the various parameters.
To set the parameters (ADDR), please refer to the table in the last pages of
the manual.

5.8.7 - System

This screen shows the loaded version of the display board software and of the power board software.
- Press the icon
EN - 40
to return to the main menu.
Param etro
Range
Defau lt
ADDR 217
Comm enti
INTER NAL
ADDIT IONAL
0 = no stages
ELECT RIC
enable d
HEATE RS
1 = 1 stage
0,1,2,3 ,4
2 = 2 stages
enable d
0
enable d
3 = 1 stage
start
enable d
for low temper
4 = 2 stages
ature
ADDR 220
start
enable d
for low temper
REMO TE
CONT ROLS
0 = none
ature
(on board
0,1,2
1 = remote
display only)
0
2 = remote
commu nicatio
switche s
n port only
ADDR 221
only
PERIO DIC
NOTE: ECO,
PUMP ACTIV
Night, DHW
ADDR 222
ATION
1=ON, 0=OFF
inputs are
and TA contac
always enable
PUMP ACTIV
1=ON
d
ts
ATION DELAY
0 -100
ADDR 223
PUMP ACTIV
hour
72
ATION LENGT
ADDR 224
H
0 – 600
second
PUMP MAINT
30
WARN ING
ENANC E
INTER VAL
ADDR 225
0-1000 day
0
WATER
FILTER
0 = disable
WARN ING
MAINT ENANC
d
INTER VAL
E
ADDR 226
0-1000 day
0
EXTER NAL
0 = disable
ADDR 227
BOILE R
REQU EST
d
1=ON, 0=OFF
T4 OUTD
0
OOR TEMP.
output 14
THRES HOLD
15
BOILE R
FOR EXTER
REQU EST
NAL
-15 to 20°C
2
ADDR 228
DOME STIC
HOT WATER
0,1,2
0 = disable
ADDR 229
2
d
LEGIO NARY
1 = set by
DISEA SE
2 = set by
DHW input
SELEC TION
MODE
DHW sensor
0 = heat
T3
0,1,2
pump+ electric
ADDR 230
0
K5)
heater (outpu
LEGIO NARY
1 = electric
t K5
DISEA SE
heater only
FUNCT ION
SAFET Y
0 – 30
2 = EH1
(outpu t K5
INTER VAL
day
EH2 electric
K5)
ADDR 231
heater s
LEGIO NARY
0
DISEA SE
FUNCT ION
SAFET Y
0 = disable
START TIME
00.00 –
d
ADDR 232
23.59
LEGIO NARY
02.00
DISEA SE
FUNCT ION
SAFET Y
TEMPE RATUR
50°C – 80°C
ADDR 233
E
LEGIO NARY
65°C
DISEA SE
FUNCT ION
SAFET Y
DURAT ION
0 – 240
ADDR 234
minute
FORC ED
30
WATER
ACTIV ATION
PUMP
0,1
0
0 = disable
1 = enable
d
d
X- 1
AC QU AD
UE SM
AL L