Starting Operation - ProMinent DULCO Trans 40/1000 PP Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety instructions Hand nozzle
Safety instructions Hand nozzle
 Transfer clean and uncharges liquids only.
 Do not exceed maximum operating pressure of 2 bar at 50°C.
 When filling into a container, make sure that no excess
pressure will be built up - danger of liquid splashing.
 Do not transfer liquid at high speed to avoid splashing
of liquids.
 Comply with all relevant safety instructions.
Wear appropriate protective clothing.
(face shield, protective gloves, etc.)
 Ensure that the hose is securely fixed to the hosetail.
 Do not mechanically overstress swivel joint. The hand
nozzle is not appropriate for pulling the flexible hose.
To avoid mechanical stress on the hand nozzle,
slightly bend the flexible hose only.
 The hand nozzle may not be used for liquids which are not
compatible with its materials of construction (nozzle housing,
nozzle valve, seal, hose ...). Also confer to resistance chart.
 Never leave the hand nozzle unattended because it does
not close automatically.
 Before starting operation, check if lever is reset automatically
to starting position.
 The outside condition of the hand nozzle has to be controlled
by regular visible checks. Regularly check swivel joint (hose
connector with o-ring), housing, outlet tube and safety handle.
These parts are particularly subject to wear and dirt
accumulation.
 Regularly check the hose clamp for tight fit.
.
Safety instructions Hand nozzle, Starting operation
 Check outlet tube and seal for tight fit. If necessary,
tighten again outlet tube and/or replace seal.
 When using a hand nozzle with an attached key button,
only use the key button with a safety extra-low voltage.
Generally replace a defect signalling cable.
 Only use the hand nozzle with safety handle.
 Non-compliance with the safety instructions may cause
injuries to the operator, pollution of the environment or
damage to the hand nozzle.

Starting operation

 Ensure that the supply voltage corresponds with
the voltage indicated on the name plate.
 Never operate the pump unless the union nut between
motor and pump has been firmly tightened.
 Immerse the pump vertically into the liquid and secure it in a
vertical position by the use of a barrel fitting or a screw clamp.
 Always check power supply cable for damage
before starting operation.
 Keep solvents away from the power supply cable.
 Only switch the motor on when the pump is in the liquid.
 Before inserting the plug to the socket, ensure that
on/off-switch is set to "0" (Stop).
 Insert the plug.
 Switch on the motor.
16