Total time 4 min
frequency 6 Hz
F10*
impulse width 200µs
Total time 4 min
frequency 6 Hz
F11*
impulse width 300µs
Total time 30 min (20 sec
5Hz - 200µs 100% + 20
F12
sec 8Hz - 150µs 100% +
20 sec 12Hz - 100µs
100%) x 30 cicles
Total time 10 min
frequency 6 Hz
F13*
impulse width 250µs
Total time 4 min
frequency 6 Hz
F14*
impulse width 250µs
Total time 3 min
F15*
frequency 6 Hz
impulse width 200µs
Total time 3 min
F16*
frequency 6 Hz
impulse width 300µs
Total time 3 min
F17*
frequency 6 Hz
impulse width 200µs
Total time 3 min
F18*
frequency 6 Hz
impulse width 300µs
Total time 10 min (3Hz-
250µs x 7sec 80%+ 1Hz-
F19*
250µs x 3sec 100% +
20Hz 250µs x 5 sec 80%)
x 40 cicles
Total time 5 min
F20*
frequency 3 Hz
impulse width 250µs
IACER S r
Total time 10 min (3Hz-
200µs x 12sec 90%+ 1Hz
200µs x 3 sec 100% +
100Hz-200µs x 5 sec
80%) x 30 cicles
Total time 10 min (3Hz-
300µs x 12sec 90%+ 1Hz
300µs x 3 sec 100% +
100Hz-300µs x 5 sec
80%) x 30 cicles
Total time 5 min (5Hz-
250µs x 7sec 80%+ 1Hz
250µs x 3 sec 100% +
20Hz-250µs x 5 sec 80%)
x 20 cicles
Total time 15 min (5Hz-
250µs x 8sec CH1&CH2
80%+ 50Hz 250µs x 6
sec 75% CH1 + 50Hz
250µs x 6 sec 75% CH2)
x 45 cicles
Total time 10 min (30Hz-
200µs x 5 sec 80% CH1
+ 30Hz-200µs x 5 sec
80% CH2) x 60 cicles
Total time 10 min (30Hz-
300µs x 5 sec 80% CH1
+ 30Hz-300µs x 5 sec
80% CH2) x 60 cicles
Total time 10 min (50Hz-
200µs x 5 sec 75% CH1
+ 50Hz-200µs x 5 sec
75% CH2) x 60 cicles
Total time 10 min (50Hz-
300µs x 5 sec 75% CH1
+ 50Hz-300µs x 5 sec
75% CH2) x 60 cicles
Total time 10 min
frequency 6 Hz
impulse width 250µs
(90%)
Total time 10 min (3Hz-
250µs x 2 sec ch1 100%
+ 3Hz-250µs x 2 sec ch2
100%) x 150 cicles
55
Total time 10 min (3Hz-
200µs x 12sec 90%+ 1Hz
200µs x 3 sec 100% +
120Hz-200µs x 5 sec
80%) x 30 cicles
Total time 10 min (3Hz-
300µs x 12sec 90%+ 1Hz
300µs x 3 sec 100% +
120Hz-300µs x 5 sec
80%) x 30 cicles
Total time 10 min
frequency 2 Hz
impulse width 250µs
Total time 5 min
frequency 10 Hz
impulse width 250µs
(80%)
Total time 5 min
frequency 4 Hz
impulse width 200µs
(90%)
Total time 5 min
frequency 4 Hz
impulse width 300µs
(90%)
Total time 5 min
frequency 4 Hz
impulse width 200µs
(90%)
Total time 5 min
frequency 4 Hz
impulse width 300µs
(90%)
Total time 10 min
frequency 2 Hz
impulse width 250µs
Total time 10 min (2Hz-
250µs x 2 sec ch1 100%
+ 2Hz-250µs x 2 sec ch2
100%) x 150 cicles
PG95 Rev 02 Ed 31 01 12