4.
Technical Data
Ambient Conditions
Temperature range
Storage and transport temperature
Protection
Altitude / installation height above sea level
Relative humidity
Electrical Data
Supply power
No-load current I
0
Current consumption device with magnet
switched on
Operating current
Protection class
Rated impulse withstand voltage U imp
Overvoltage category
Pollution degree
Rated insulation voltage U i
Rated operating voltage U e
Rated operating current I e
Conditional rated short-circuit current
External line and equipment protection
Duty cycle of magnet
Response time
Risk time
Ready-state delay
Switching frequency
Safety Output OSSD 1 / OSSD 2
Safety output
Number of safety outputs
Rated operating voltage U e1
Rated operating current I e1
Voltage drop at safety output
Residual current I r
Utilization category
Test pulse duration
Test pulse interval
ZVEI classification
Source
Sink
Safety Input IN 1 / IN 2
Number of safety inputs
Voltage range
Accepted test pulse duration to input signal
With a test pulse interval of
ZVEI classification
Source
Sink
Safety Interlocks electromagnetic / Safety Switch with interlocking function
−25 to 55° C
−25 to 70° C
IP65 / IP67
max. 2000 m
30 to 95 % (no condensation or icing allowed)
20.0 to 26.4 V DC (stabilized PELV power pack per EN 60204-1)
< 0,1 A
Average: < 0,35 A
< 0,55 A / 10 ms
Peak current:
Max. 0.6 A plus current via safety outputs
III
0.8 kV
III
3
32 V
24 V
1,1 A
100 A
2 A gG
100 %
< 150 ms
< 150 ms
< 4000 ms
≤ 1 Hz
Semiconductor, NO function, PNP output, short-circuit proof
2
24 V
≤ 250 mA
≤ 1 V
≤ 0.5 mA
DC-13
≤ 1,0 ms
1000 ms
ZVEI CB24I
C1
C1
2
−3 to 5 V (low), (stabilized PELV power pack per EN 60204-1)
15 to 30 V (high), (stabilized PELV power pack per EN 60204-1)
≤ 1,0 ms
≥ 100 ms
ZVEI CB24I
C1, C2, C3
C1
29