first!! (e.g. E4).
• Make sure the module remains in setup mode.
• Press button marked with "All Off" 2x (= mute).
• The MicroModule responds by blinking the LED 8x.
NOTES:
• When you program the MicroModule, always program the
address first the optional functions second.
• If the MicroModule receives a new address during setup mode,
the optional functions will be automatically reset to the default
settings.
USAGE OF THE MICROMODULES IN A 3 PHASE
INSTALLATION
The X10 transmitters of the MicroModules transmit the command
only once for use in the phase of which they are connected.
When you want to receive the commands on your other phases
as well, you will need to install the CAT3000 phase
coupler/repeater.
The FD10 phase coupling filters can be used as netfilters, but not
as phase couplers in combination with the LWM1.
TESTING THE FUSE
Test the performance of the fuse (type TR5-1, 6 AT).
Disconnect the LWM1 from the load (lamp, transformer). Then
measure the voltage on the output clamp with a voltmeter. If
there is no voltage, the fuse is defective.
NOTE: In case of a melted fuse the programming LED still
blinks.
LWM1
TM
13