5.1 Maintenance and wearing parts
You have purchased a product that is durable and easy to service.
However, all technical equipment requires regular servicing in order to guarantee optimal functionality.
If the product malfunctions during the warranty period, contact your contract partner, the installation company,
and quote the unit type and production number (see technical specifications or the type plate on the unit).
Please exchange the wearing parts in the specified main tenance intervals:
Please observe!
regular intervals by our service technicians, at least however, once a year.
✔ Consider as well the instruction manual of the external installed pre-filter.
✔ Prior to working on electric components and a opened housing, ensure carefully that the device
has been deactivated by unplugging the mains plug and therefore has zero potential.
✔ Any maintenance work should include a check of the connecting lines and the housing.
Note: The replacement of the wearing parts must be effected by
qualified compartment staff. (Plumber or customer BWT service).
Exchange of wearing parts:
Maintenance work:
✔ General visual inspection
✔ Check of tightness
✔ Cleaning with a moist cloth
✔ Conductivity (value displayed by RO)
➤ Conductivity (value of measuring device)
➤ Exchange of the external pre-filter insert (100μm)
➤ Exchange RO membrane elements
➤ Exchange of high-pressure pump head
➤ Exchange of connections/pressure hoses
➤ Water hardness test
Please observe: According to BGV A2 (VBG4), the electrical safety check is to be conducted every 4 years.
The BWT bestaqua 14, 18 devices have been designed in compliance with the "Pressure Equipment Directive" 97/23/
EC of 29
May 2007. Therefore, it meets the requirements of Article 3, Section 3, and is consequently manufactured and
th
assembled in accordance with applicable good engineering practice.
The BWT bestaqua 14, 18 devices do not receive a CE mark in accordance with Article 15 of Directive 97/23/ EC.
However, the attached EC declaration of incorporation is applicable.
Note: To ensure reliable production and to meet the requirements of our customers or to extend the warranty, our
company offers the conclusion of a BWT service contract.
✔ BWT service or a contract guarantees the professional, regular examination in which all important components
are cleaned, checked and in which wearing parts are replaced.
✔ Please ask about our services.
Responsible:
Recommended maintenance interval:
Customer
Weekly
Customer
Weekly
Customer
As required
Customer
Weekly
Customer, service
At least, once a year
Customer, service
At least, 2 times a year
Service
At least, once a year
Service
Every 2 years
Service
Every 5 years
Service
At least, once a year
maintenance is to be performed at