EN
START
Fig.
WCF MIN
27
WCF MAX
PRESSURE STOP MAX
PRESSURE START MAX
STOP TIME DELAY
MAX PUMP PRESSURE
RINSE TIME
WATER FILL UP TIME
4.0 BAR
Set max stop pressure
3.0 BAR
Set max stop pressure
3.0 BAR
Set max stop pressure
3.5 BAR
Set max stop pressure
3.5 BAR
Set max stop pressure
Adjustment range
PRESSURE STOP MAX:
1.0 ... 7.0 bar
Fig. 28: Programming procedure: INSTALLATION 2/3
50
START
WCF MIN
WCF MAX
PRESSURE STOP MAX
PRESSURE START MAX
STOP TIME DELAY
MAX PUMP PRESSURE
RINSE TIME
WATER FILL UP TIME
1.5 BAR
Set max start pressure
2.5 BAR
Set max start pressure
2.5 BAR
Set max start pressure
2.1 BAR
Set max start pressure
2.1 BAR
Set max start pressure
Adjustment range
PRESSURE START MAX:
1.0 ... 7.0 bar
WCF MIN
WCF MAX
PRESSURE STOP MAX
PRESSURE START MAX
STOP TIME DELAY
MAX PUMP PRESSURE
RINSE TIME
WATER FILL UP TIME
00 sec
Set stop time delay
00 sec
Set stop time delay
00 sec
Set stop time delay
09 sec
Set stop time delay
09 sec
Set stop time delay
Adjustment range
STOP TIME DELAY:
0 ... 19 s
Fig.
29