SIMATIC VS710
Characteristic
Technical Specifications
Climatic Conditions
Temperature
Tested according to IEC 68-2-1, IEC 68-2-2
Operation
0 C to + 50 C
Rate of temperature change max. 10 C/h
Storage/trans-
-20 C to +70 C
port
Rate of temperature change max. 20 C/h
Relative humidity
Tested according to IEC 68-2-3
Operation
5% to 95% at 25 C (no condensation)
Storage/trans-
5% to 95% at 25 C (no condensation)
port
Atmospheric
pressure
1080-795 hPa (
Operation
1080-660 hPa (
Storage/trans-
port
Mechanical Environmental Conditions (without lens)
Vibration
Tested according to IEC 68-2-6
Operation
10 to 58 Hz, amplitude 0.075 mm
58 to 500 Hz, acceleration 9.8 m/s
Storage/trans-
5 to 9 Hz, amplitude 3.5 mm
port
9 to 500 Hz, acceleration 9.8 m/s
Shock
Tested according to IEC 68-2-27/29
Operation
Semi-sinusoidal: 100 m/s
16ms, 100 shocks
Semi-sinusoidal: 700 m/s
Storage/trans-
6ms, 3 shocks
port
Semi-sinusoidal: 250 m/s
6ms, 1000 shocks
Note
The absolute brightness values of the image may vary slightly, depending
on the physical properties of the CCD chip and the temperature range.
28
Quick Reference Guide
-1000 m to +2000 m)
-1000 m to +3500 m)
2
2
2
(
,
10 g)
2
(7
0 g)
,
2
(25 g),