7 Electrical connection

WARNING OF ELECTRICAL ENERGY!
RISK OF FATAL INJURY!
Live components have been installed near
this symbol. Covers bearing this sign may
only be removed by a certifi ed skilled electri-
cian.
The electrical connection must be carried out by a
qualifi ed electrician who is authorised to carry out such
work!
Statutory regulations and the connection specifi cations
issued by the local power supply company must be
strictly observed.
When connecting the appliance it must be ensured that
there is a device which makes it possible to universally
disconnect it from the mains with a contact opening
width of at least 3mm. Line-protecting switches, fuses
or contactors are suitable cut-out devices. When
connecting and repairing the appliance disconnect it
from the electricity supply with one of these devices.
The earth wire must be suffi ciently long so that if the
strain relief fails, the live wires of the connecting cable
are subjected to tension before the earth wire.
Any superfl uous cable must be removed from the ins-
tallation area beneath the appliance.
Make sure that the local mains voltage is the same as
the voltage on the rating label.
Full protection against accidental contact must be en-
sured on installation.
Attention: Incorrect connection may result in the power
electronics unit being destroyed.
The appliance is only authorised for permanent
connection. It may not be connected with a shock-proof
plug.
Power supply
Mains voltage: 380-415V 2N~, 50/60Hz
Component rated voltage: 220-240V
36
Electrical connection
Mains cable available in the factory
The hob has been fi tted with a temperature-resistant
connection cable in the factory.
Connection to the mains is carried out in accordance
with the circuit diagram, unless the connection cable is
already fi tted with a plug.
If the mains cable of this appliance is damaged it will
need to be replaced with a special connection cable. In
order to avoid any risks, this must be carried out by the
manufacturer or his Customer Service.
Electrical connections

8 Technical data

Hob dimensions
height/ width/ depth ...mm
Cooking zones
all zones ............cm / kW
Hob ..............................kW
* Power when the power boost function is activated

9 Putting the appliance into operation

Once the hob has been installed and the power supply has
been provided (mains connected) an automatic test of the
controls will be carried out and information for Customer
Service will be indicated.
Important: No items may be on the touch control sensor
keys when the appliance is being connected!
Briefl y wipe over the surface of the hob with a sponge and
soapy water and then dry with a clean cloth.
GB
155 x 834 x 515
19x22/ 2.1 (3.7)*