Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential safety
breaker close to the appliance.
2 - Undo the screws (C) and remove the control
panel (D).
3 - Connect the circuit-breaker (A) to the terminal
board (E) of the appliance as shown in the dia-
gram and in the electrical system diagram at the
back of the manual. Use a flexible cable with at
least type H07RN-F characteristics, rated for an
operating temperature of at least 80°C.
CONVERSION OF ELECTRICITY SUPPLY (090FTE-190FTE)
Important
The appliance is supplied at an operating
voltage 400V/3N (indicated on the sticker ap-
plied to the dataplate); conversion to 230V/3
can be carried out as described below.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
1 - Undo the screws (B) and remove the control
panel (C).
2 - Modify the connections to the heating element
terminals (D) as shown in the electrical system
diagram at the back of the manual.
3 - Disconnect wire 11 from the neutral (models
090FTE only) or wires 39-40 from the neutral
(models 190FTE only) and fit the jumper (E)
When connecting, take care to connect the
neutral and earth lines.
A
C
D
- 21 -
Important
4 - Tighten the cable gland (F).
5 - Replace the control panel (D) on completion of
the operation.
C
E
F
E
B
B
C
across L3 and the neutral as shown in the dia-
gram and in the electrical system diagram at
the back of the manual.
4 - Replace the control panel (C) on completion of
the operation.