FRIGOLATTE FL 11 - BACK C
installation
VENTILATION
• For built-in units, fit the refrigerator in the furnishing unit in such a way that the fan protrudes from the
ventilation duct and guarantee that there is a section for the air intake and outlet of at least 200 cm
Leave 60 mm free between the frigolatte and the furniture on the top, left and right sides.
WIRING CONNECTIONS AND EARTHING
Before putting the plug into the power socket, make sure the mains voltage is the same as the one shown
on the technical specification plate (located inside the frigolatte) and that the socket is equipped with
proper earthing, as laid down in the regulations on wiring system safety. Also, the power socket must
be able to hold up to the maximum power of the device, shown on the same plate.
Caution!
If the socket is not equipped with an earthing system or if multiple sockets or adaptors are used, the Ma-
nufacturer will not be liable for any injury or damage to things and/or to the frigolatte.
Caution!
The user must always be able to access the power supply socket.
Caution!
If you uninstall the fridge, you must take off the front door.
Uso
The FL11 series of Frigolatte units have a thermostat located on top of the fridge (the temperature is
adjusted at optimum operating levels). When the frigolatte is connected to the mains power supply it
switches on automatically.
FRIGOLATTE FL 11 - BACK C 00_29-05-2015
ENGLISH
.
2
9