12. Tips and notes
•
Light refraction and sunlight can cause measuring errors during
outdoor use. Perform measurements under suitable light conditions.
•
When using the product outdoors, protect it from moisture and
humidity.
•
The following surfaces can affect the measurement due to their
physical characteristics:
- Transparent surfaces (e.g. glass, water)
- Reflecting surfaces (e.g. glass, shiny metals)
- Porous surfaces (e.g. insulating materials)
- Structured surfaces (e.g. roughcast, natural stone)
•
Attach the hand strap to the eyelet located in the lower right area
of the housing.
13. Troubleshooting
Code
Cause
Reflected signal too
ERR01
strong
Measurement range
ERR02
exceeded
Reflected signal too
ERR03
weak
ERR06
Batteries weak
Solution
Select another measurement
surface or attach a sheet of
white paper to the surface.
Observe the correct
measurement range.
Select another measurement
surface or attach a sheet of
white paper to the surface.
Replace the batteries.
31