REPLACEMENT OF THE BURNER NOZZLE

To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (B) and remove the control
panel (C).
4 - Unscrew the nozzle (D) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - Replace the control panel (C) and the knobs (A)
on completion of the operation.
REPLACEMENT OF THE PILOT LIGHT INJECTOR
To carry out this operation, proceed as fol-
lows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (B) and remove the control
panel (C).
4 - Unscrew the union (D).
5 - Remove the nozzle (E) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
IT
6 - Retighten the union (D).
7 - Replace the control panel (C) and the knobs (A)
GB
on completion of the operation.
DE
FR

DECOMMISSIONING THE APPLIANCE

ES
Important
This operation must be carried out by
skilled operatives in compliance with the le-
gal requirements with regard to safety at
work. Never dump non-biodegradable ma-
terials, lubricating oils and non-metallic
English
A
B
C
A
B
C
components (rubber, PVC, resins, etc.) in
the environment. Dispose of them in ac-
cordance with the relevant legal require-