Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ADJUSTING BURNER PRIMARY AIR
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panel (B).
4 - Undo the locking screw (D).
5 - Set the bush (E) in contact at the distance (F)
shown in the table.
6 - Tighten the screw (D).
7 - Replace the control panel (B) and the knobs (A)
on completion of the operation.
Gas family
II (G20/20-25 mbar)
II (G 25/20-25mbar)
III (G30-31/29-36/37 mbar)
III (G 30-31/50mbar)
RECOMMENDATIONS FOR REPLACING PARTS
Before carrying out any replacement procedure, ac-
tivate all the safety devices provided and decide
whether staff at work and those in the vicinity
should be informed. In particular, turn off the gas
supply tap and prevent access to all devices which
might cause unexpected health and safety hazards
if turned on. If work parts have to be replaced, use
original spare parts only.
Distance (F) (mm)
24±1
24±1
24±1/
24±1/

REPLACING PARTS

- 23 -
C
A
C
B
The manufacturer declines all responsibly for injury
or damage to components due to the use of non
original parts, or extraordinary work on the appli-
ance which may modify the safety requirements
without the manufacturer's authorisation.
When ordering components, follow the instructions
provided in the parts catalogue.
E
D
IDM-39614702000.tif