To test the system, make the following checks:
1 - check that the mains voltage is the same as that
of the appliance;
2 - operate the appliance's circuit-breaker to check
the electrical connection;
RECOMMENDATIONS FOR ADJUSTMENTS
Important
Before making any type of adjustment, acti-
vate all the safety devices provided and de-
cide whether staff at work and those in the
vicinity should be informed. In particular,
turn off the water supply tap, cut off the
ADJUSTING THE LID COUNTER-BALANCING
To carry out this operation, proceed as fol-
lows.
1 - Fit the spanner (A) onto the hexagon (B).
2 - Keep a firm grip on the spanner (A) and undo
the locking screws (C).
3 - Turn the spanner (A) clockwise to load the
spring or anti-clockwise to release it.
4 - Once the correct balance is obtained, screw in
IT
the screws (C) without tightening them fully.
5 - Use the spanner (A) to turn the shaft until it is
GB
located in one of the seats provided.
6 - Fully tighten the screws (C).
DE
FR
ES
The appliance does not require the replacement of
operating components by specialist staff except the
DECOMMISSIONING THE APPLIANCE
Important
This operation must be carried out by skilled
operatives in compliance with the legal re-
quirements with regard to safety at work.
Never dump non-biodegradable materials, lu-
bricating oils and non-metallic components
English
ADJUSTMENTS
REPLACING PARTS
- 16 -
3 - check that the safety device is operating cor-
rectly.
After testing, if necessary instruct the user in all the
skills necessary for putting the appliance into oper-
ation in conditions of safety, in accordance with le-
electricity supply using the master switch
and prevent access to all devices that
might cause unexpected health and safety
hazards if turned on.
A
C
B
replacement of standard parts which can be carried
out by the user.
(rubber, PVC, resins, etc.) in the environ-
ment. Dispose of them in accordance with
the relevant legal requirements.
8
IDM-39603603200.tif
9