Electrical/hydraulic connection
Connection
Based on provisions of field professional organisations "CE", all splitters have been fitted with an undervoltage release in the switch.
This prevents appliance self-starting in case supply is interrupted as a result of power failure, unintentional unplugging, defective fuse,
etc. The appliance must necessarily be switched on by pressing the green switch button.
Intentional holding or blocking the switch button with a neutral conductor missing leads to automatic switch outage. In such a case that
may subsequently be identified, the warranty will not apply.
Only for 400 V appliances:
The engine rotation direction (see the arrow on the appliance) must be respected as
running with wrong rotation direction may damage the oil pump. In such a case, all
claims arising from the warranty will not apply. If necessary, have the rotation
direction changed by reversing the plug polarity by a professional electrician. See
the picture! (three-phase models only!)
Hydraulic equipment
Tightness must be checked at hydraulic hoses and couplings after app. 4 hours of
operation and tightening provided if necessary.
Hydraulic oil/tank
Common hydraulic oil (e.g. BHLP 46 or oil with the same viscosity of another manufacturer) may be
added to all splitters.
Transport instructions
Transport
All log splitters have been fitted with big wheels. To transport the splitter, grab the splitter post handle with one hand and the handle
above the engine by the other hand and tilt slightly the splitter to you. In this position, the splitter may easily be moved.
To prevent hydraulic oil leak, the splitter must never be moved when laying.
Lower the splitting knife down to full extent when moving the appliance.
Warranty
A warranty period of 12 months applies to commercial use and 24 months apply to private use and commences on the day of purchase
of the device. Warranty applies exclusively to failures due to defective material or workmanship. An original sale slip with indication of
date of sale must be presented in case of claiming for the warranty rights. Warranty does not cover unprofessional use such as device
overload, violent use, damage caused by third party or foreign materials, failure to comply with operations and assembly manual, and
normal wear and tear.
Failures
Failure
No splitter power
After being pressed, the green switch
button not remaining pressed
Hydraulic pump whistling; splitting knife
jerky
No works other than works for which the appliance has been designed and that are specified in these Operating Instructions
Cause
-
Wrong rotation direction (400 V only)
-
Too little of hydraulic oil
-
Switching rod is bent; hydraulic lifter
not pressed to full extent
-
Neutral not connected
-
Defective fuse, etc. (400 V only)
-
2-phase running (400 V)
Too little of hydraulic oil
-
may be performed with this appliance.
16
Remedy
-
Have the rotation direction changed by
a professional
-
Add hydraulic oil
Adjust the rod mechanism; tighten the
-
appropriate nuts.
-
Have the cable or network checked by
a professional
-
Check the cable
-
Add hydraulic oil