Quick Operation Guide
5. MAINTENANCE.
5.1 - Regularly check the state of the cable. If
the cable has broken threads, or if it shows any
signs of crushed/flattened areas, it should be
changed and replaced immediately with a new
one. Do not use the lift if the cables are in bad
condition. Only use steel cables reference:
DIN 3060 torsion resistant.
5.2 - The lift is supplied from the factory
completely greased. However, it is
recommended to periodically grease according
to use, the gearing, the axis bearings, the
spiral of the crank, and the sections.
REMEMBER: NEVER grease or lubricate
the breaking mechanism.
It is not necessary to grease the brake disks.
The brake disks have been greased with a
special heat and pressure resistant solution.
Other products should not be used to avoid
negative effects regarding the braking
mechanism.
5.3 - An expert should check the Towerlift at
least once a year according to its usage. Consult
your distributor.
5.4 - Only original replacement parts should be
used to guarantee continued safety during
usage.
The user loses all guarantee rights if he/she uses
replacement parts that are not original or if he/
she makes any modification to the apparatus.
5.5 - To order any replacement parts, the
reference number on the replacement parts
pages in this manual should be indicated.
PRO LIFTS S.L.
ENGLISH
6. GUARANTEE.
If the during the guarantee period because of
poor workmanship or faulty materials PRO
LIFTS S.L. will repair or replace it.
The guarantee period for Europe is at 2
years.
The guarantee does not cover damage
caused by improper use, wear and tear
unauthorised repairs. The guarantee does not
cover consumables or defects that have only
a negligible effect on the value or operation of
the elevator tower.