Technical Data - ESAB Caddy Mig C200i Manuel D'instructions

Masquer les pouces Voir aussi pour Caddy Mig C200i:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

US
3

TECHNICAL DATA

Mains voltage
Permissible load at
25 % duty cycle
60 % duty cycle
100 % duty cycle
Setting range
Open circuit voltage
Open circuit power
Efficiency at maximum current
Power factor at maximum current
Wire feed speed
Wire diameter
Fe
Cored wire
Ss
Al
Max. diameter wire bobbin
Continual sound pressure at no-load
Dimensions lxwxh
Weight
Operating temperature
Transportation temperature
Enclosure class
Application classification
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld at a cer­
tain load without overloading. The duty cycle is valid for 104° F.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23C is designed for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.
bc22a
Mig C200i
230 V, 1 50/60 Hz
180 A
120 A
100 A
30 A - 200 A
60 V
15 W
82%
0.99
6.6 - 39.4"/min
 .024 - .040"
 .030 - .040"
 .030 - .040"
 .40"
 7.9"
< 70 dB
17.7 x 7.8 x 13.7"
26.5 lbs
14 - 104° F
-4 - 131°F
IP 23C
- 11 -