EyeVolution ® MAX
6. Functional elements
8
6
5
No. Description
1
Power supply connector socket
2
Main switch
3
Display foil
4
Time programme push-button
5
Rotary plate function push-button
6
Function display
7
Rotary plate
8
Reflective foil
9
LED circuit board
10
Glare protection
11
Cover handle
12
Device cover
13
Inspection window
22
13
12
11
10
9
7
3
4
2
1
7. Operation
Activate the main switch (2) on the back
lum plate is recommended for exclusively
of the device; the functional display LED
occlusal modelling (e.g. inlay or onlay).
(6) lights up in red. The device is now
ready for operation.
Open the polymerisation chamber by
raising the device cover (12) at the han-
dle (11). The opening angle is approx.
55° and is fixed in its final position by
a magnet.
The central point of the surface that is
to be polymerised must always be posi-
tioned on the seating for the model at a
distance of 2-3 cm from the middle LED
Release the cover from its magnetic
that has a black circle round it.
anchoring by pulling slightly on the han-
Fixing the model vertically on the pendu-
dle and close the polymerisation chamber.
7.1 Time programmes
The EyeVolution® MAX light-curing
Opaquer: 1:00–2:00 min
device features several pre-programmed
Pre-polymerisation: 0:30–1:00 min
time relays. Use the push-button (4) to
Interim polymerisation: 1:00–2:00 min
activate time programmes with 1 / 2 / 3 / 5
End polymerisation: 2:00–5:00 min
and 10 minutes.
Start the selected time programme by
The following times apply, depending
pressing the corresponding push-button
on the composite material that is being
(4). The polymerisation process starts
used and for a maximum layer thickness
automatically and is indicated as an
of 2 mm:
active programme by a green LED.
7.2 Rotary plate
grammes and is automatically activated
A reflective pendulum plate (7) was
when the polymerisation programme starts.
designed for the seating of the model to
The LED (6) indicates the operating status
ensure optimum polymerisation with as
of the rotary plate:
little shadowing as possible. Starting in a
Green LED = rotary plate in action
central position (see point 7.1), the seating
Red LED = rotary function deactivated
of the model first moves to the right by 90°
Use the push-button (5) to activate or deac-
after the program is started and then shifts
tivate the rotary plate function at any time,
into a 180° pendular motion. The oscilla-
even during on-going polymerisation pro-
tion function is coupled with the time pro-
grammes.
optimal
start position
23