ture.
2) The showcase will not cool properly
• the condenser may be dirty and therefore unable to exchange heat. If it is obstructed with dust or dirt, clean tho-
roughly as explained in section 10;
• make sure that the product load is correct (see section 7);
• if the showcase has not been defrosted for longer than 3 months, defrost and clean it before starting normal ope-
ration (see section 10, item 4);
• make sure that the case is not exposed to sources of heat or draught;
• make certain that ambient conditions comply with the requirements of page 4, table II;
• check that the showcase is perfectly horizontal by the use of a spirit level.
Should insufficient cooling persist, resort to the nearest after-sales service.
IN CASE OF A GAS LEAK OR FIRE, do not breathe inside the room that houses the cabinet before having
aired it properly. Turn the cabinet off by the main switch ahead (see fig. 19). DO NOT USE WATER BUT ONLY
DRY EXTINGUISHERS TO PUT OUT THE FIRE.
3) The cabinet operates noisily:
• make sure that screws and bolts are securely closed;
• check that the showcase is perfectly horizontal by the use of a spirit level.
Should the inconvenience persist, resort to the nearest after-sales service.
12. AFTER-SALES SERVICE
Should it be necessary to resort to technical assistance, contact your sales person immediately. If spare parts are nee-
ded, always refer to your after-sales service: insist on the use of original spare parts. Scroll the Italian and
European network of branch offices on the back of this manual for addresses and phone numbers.
13. DISMANTLING AND DISPOSAL
For the sake of the environment, please sort the parts and materials composing the cabinet in accordance with the
waste disposal provisions in force in your country, so that they can be properly disposed of or recycled. All its parts
cannot be treated as solid urban waste, except for the metal parts, which nevertheless are not considered as special
waste by most European countries. THE PARTS COMPOSING THE REFRIGERATING CIRCUIT MUST NOT BE
SEVERED OR SEPARATED BUT DELIVERED INTACT TO A CENTRE SPECIALISED IN RECYCLING REFRIGERANT
GAS.