6.2 WIRING

CHECK that the receiving unit power supply is within the voltage range given
in the "Technical Data", and that the voltages and currents being used do not
exceed the maximum permitted values.
POWER the receiving unit downstream of the main switch of the electrical pan-
el.
POWER THE RECEIVING UNIT WITH A SAFETY ISOLATING TRANSFORMER.
The receiving unit POWER SUPPLY must be protected from short circuit.
The arrangement of output and power supply terminals of the receiving and the extension
units is labelled directly on the units (see technical data sheet for the wiring).
Power supply must be connected to the receiving unit as explained in the diagrams that fol-
low:
AC
DC
+
-
The receiving unit is connected to its extension through a
flat cable that has to be inserted into the connector near to
the antenna connector.
LIE&LQU4-01 - eng.fm
V1 V2
0Vac
24Vac
Diode 1A 400V
(i.e. 1N4004)
V1 V2
0Vac
24Vac
V1 V2
6 - Installation
0Vac
24Vac
48Vac
Diode 1A 400V
(i.e. 1N4004)
0Vac
24Vac
48Vac
+
-
V1 V2
V1 V2
V1 V2
Page 27