Receiving And Extension Unit Technical Data; Air Pressure - AUtec E16SRXEU1 Manuel De L'utilisateur

Radiocommandes industrielles
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3.3 RECEIVING AND EXTENSION UNIT TECHNICAL DATA

Climatic conditions
WORKING
STORAGE
TRANSPORTATION
SAFETY contact rated current .................................................................... 4A (250Vac)
Command contact rated current.................................................................. 4A (250Vac)
Housing ........................................................................................................... NORIL ®
Protection degree.....................................................................................................IP20
Receiving unit
Supply voltage..................................................................... Nom. 12 -24 Vac/dc (~7 W)
.............................................................................................
Antenna.......................................................................................................... dedicated
Number of available commands..........................................................14 (+ start + stop)
STOP contact rated current ........................................................................ 4A (250Vac)
Fuse F3 (STOP circuit) ................................................................4A T 250V (5x20 mm)
Fuse F2 (SAFETY circuit) ............................................................4A T 250V (5x20 mm)
Fuse F1 (POWER SUPPLY)....................................................... 1A T 250V (5x20 mm)
Dimensions .................................................................................... (160 x 110 x 75) mm
Weight ................................................................................................................... 500 g
Extension unit
Number of available commands.................................................................................... 6
Fuse F4 (SAFETY circuit) ............................................................4A T 250V (5x20 mm)
Dimensions ...................................................................................... (72 x 110 x 75) mm
Weight ................................................................................................................... 200 g
Page 22
TEMPERATURE RELATIVE HUMIDITY
Class 4K4H
Class 4K4H
-20°C to +70°C
4% to 100%
Class 1K5
-40°C to +70°C
Class 2K3
-25°C to +70°C
3 - Receiving unit

AIR PRESSURE

86 kPa to 106 kPa
Class 1K3
5% to 95%
86 kPa to 106 kPa
Class 2K3
95%
70 kPa to 106 kPa
Max. 10 -30 Vac/dc (~7 W)
Class 4K4H
Class 1K4
Class 2K3
LIE&LQU4-01 - eng.fm

Publicité

Table des Matières
loading

Produits Connexes pour AUtec E16SRXEU1

Ce manuel est également adapté pour:

E16srxeu2

Table des Matières