SCHOLTES SOKV1410X Manuel D'utilisation page 30

Four combiné vapeur
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

After cooking, a
noise persists and
an air flow close to
the control panel is
present
By following the
instructions in the
recipe, the food
is not sufficiently
cooked
Below defect codes may occur during steam functions:
E-06: 1-Water tank is not close well.
E-05: water system abnormal, need to contact for Engineer to check, below is the
possibilities.
The water sensor is abnormal.
The water pump is abnormal.
The water pipe is abnormal.
The water tank is abnormal.
The cooling fan is always on in order to
-
avoid humidity in the cavity and to cool
the oven. It will stop automatically.
A temperature different from that of the
recipe has been selected. Please check
-
the temperature.
Different amounts of the recipe have
been cooked. Please check the recipe.