MZ electronic EV-040 Instructions D'utilisation page 25

Radio compteur métrique
Masquer les pouces Voir aussi pour EV-040:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Standard and X.. Project series
sensor menu
(magnet and sensor placed
on barbotin)
Sensor Calibrat
Barb. Circ.
Divisor fact.
E xit
Barbotin Circumference
In this row the user must enter the
circumference of the gipsy (in centimetres or
inches). Use the Table 1 provided to
calculate the circumference.
Settable values: centimetres or inches.
Default value, 33 cm.
Division Factor
If you use the 3-wire inductive sensor set
here the number of signatures of the gypsy
obtained from Table 1.
If you use the 2-wire magnetic sensor leave
the value set to 1.
Select with
Exit
To return to the settings menu.
Table 1 - Standard and Project X.. series sensor
(magnet and sensor placed on barbotin)
Chain Type
6 mm
7 mm
8 mm
10 mm
12 mm
13 mm
14 mm
* factory settings of instrument
EV-040
33.0
1
Reduction Factor
In this row the user must enter the reduction
factor. See next Table 2 for the correct value
to be entered
Default value, 57.
Select value with
Confirm with
Number of recesses
6
9
6
5
6
7
8
5
6
5
6
6
5
1000 – 1500 –2000 W Project series
sensor menu
(magnet and sensor placed
on motor)
Sensor Calibrat
Red. Factor
E x i t
Gipsy Circumference
(cm)
22
34
25
24
28
33*
38
31
36
36
43
46
42
25
English
5 7 . 0
Confirm with
Gipsy Circumference
(inches)
9
13
10
9
11
13
15
12
14
14
17
18
16
Rev. 11 – 2018

Publicité

Table des Matières
loading

Table des Matières