Problem
Logs are not being split properly
(insufficient
splitting
performance).
Splitting
column
moves
unsteadily
or
with
vibrations.
Splitting column does not move
in.
Motor starts, but splitting column
does not move in.
Motor will not start.
s
s
Possible cause
⇒ The log is not positioned correctly.
⇒ The
log
exceeds
dimensions or the wood is too hard for
the performance of the machine.
⇒ Splitting blade does not split log.
⇒ Hydraulic pressure too low.
⇒ Release rods bent (hydraulic tappet not
quite pressed in).
⇒ Incorrect connecting lead (longer than
10 m or too small cable cross-section).
⇒ Air in the circuit.
strong
⇒ Splitting
column
lubricated or oiled.
⇒ Hydraulic pump defective.
⇒ Motor turns in wrong direction
⇒ No electrical power.
⇒ 2-phase mode in threephase motor.
⇒ Connection cable defective.
⇒ Electric motor defective.
Remedy
⇒ Reposition the log correctly.
⇒ Cut the log to the required dimensions.
the
maximum
⇒ Sharpen splitting blade, check for burrs or
notches.
⇒ Check the oil level and add more oil if
necessary.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
⇒ Arrange
company to adjust the rods.
⇒ Use the correct connecting lead.
⇒ Check the oil level and add more oil if
necessary.
not
sufficiently
⇒ Lubricate
environmentally friendly spray oil.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
⇒ To correct the problem, refer to the
manufacturer or other approved service centre.
⇒ Check the motor direction
Threephase:
(s. page 19)
AC: To correct the problem, refer to the manu-
facturer or other approved service centre.
⇒ Check the fuse.
⇒ Have fuse and lead checked by qualified
electrician.
⇒ Replace the connection cable or have it
checked by an electrician.
⇒ To correct the problem, refer to the
manufacturer or other approved service centre.