T
e
c
h
n
i
c
a
l
d
a
t
a
T
e
c
h
n
i
c
a
l
d
a
t
a
Model
Type
Splitting force
Log length
Log diameter
Stroke
Feed speed
Return speed
Hydraulic oil (max.)
Hydraulic pressure
Electric motor performance (power consumption)
Power supply
Dimensions
Weight
P
o
s
s
i
b
l
e
p
r
o
b
l
e
m
P
o
s
s
i
b
l
e
p
r
o
b
l
e
m
Problem
Logs are not being split
properly
(insufficient
splitting
performance).
Splitting column moves
unsteadily or with strong
vibrations.
Splitting column does not
move in.
Motor starts, but splitting
column does not move in.
Motor will not start.
s
s
Possible cause
⇒ The log is not positioned correctly.
⇒ The log exceeds the maximum dimensions
or the wood is too hard for the performance
of the machine.
⇒ Splitting blade does not split log.
⇒ Hydraulic pressure too low.
⇒ Release rods bent (hydraulic tappet not
quite pressed in).
⇒ Incorrect connecting lead (longer than 10 m
or too small cable cross-section).
⇒ Air in the circuit.
⇒ Splitting column not sufficiently lubricated or
oiled.
⇒ Hydraulic pump defective.
⇒ Motor turns in wrong direction
⇒ No electrical power.
⇒ 2-phase mode in threephase motor.
⇒ Connection cable defective.
⇒ Electric motor defective.
ASP 6-1050 - single phase AC
60 kN (10 t) ± 10 %
min. 120 – max. 320 mm
approx. 0.04 m/sek.
approx. 0.17 m/sek.
18 MPa (180 bar)
P
3.0 kW (S6-40%)
1
230 V~ 50 Hz, 16 A time-lag
length 740 x width 390 x height 1030 mm
approx. 120 kg
Remedy
⇒ Reposition the log correctly.
⇒ Cut the log to the required dimensions.
⇒ Sharpen splitting blade, check for burrs or
notches.
⇒ Check the oil level and add more oil if necessary.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
⇒ Arrange for manufacturer or authorised company
to adjust the rods.
⇒ Use the correct connecting lead.
⇒ Check the oil level and add more oil if necessary.
⇒ Lubricate
environmentally friendly spray oil.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
⇒ To correct the problem, refer to the manufacturer
or other approved service centre.
⇒ Check the motor direction
Threephase:
(s. page 18)
AC: To correct the problem, refer to the manu-
facturer or other approved service centre.
⇒ Check the fuse.
⇒ Have fuse and lead checked by qualified
electrician.
⇒ Replace the connection cable or have it checked
by an electrician.
⇒ To correct the problem, refer to the manufacturer
or other approved service centre.
ASP 6-1050 - three phase current
ASP 6-1050
max. 1040 mm
≈ 500 mm
4.5 litres
20 MPa (200 bar)
P
3.0 kW (S6-40%)
1
400 V 3~ 50 Hz, 16 A
approx. 117 kg
splitting
column
adjust
the
or
oil
with
motor
direction
23