Pressure Sensor Series PS400/PS500
10.2.1 Additional settings in the sub-menu EF
Parameter Explanation
HI
Max. value memory
LO
Min. value memory
COF
Offset correction
dSP
Switching delay
of SP1
drP
Switching delay
of rP1
16
/0805
Hans Turck GmbH & Co.KG • D–45466 Mülheim an der Ruhr • www.turck.com
Options
Function
The highest pressure
value is stored in the
non-volatile memory.
The lowest pressure
value is stored in the
non-volatile memory.
Significant thermal
changes in the sensor
environment can lead to
zero shift. As a result,
the measuring value
displayed in a pressure-
less state will not accord
to zero. This drift can be
corrected.
Adjustment range:
-5 to +5 % of the
measuring span
in increments of 0.1 %
0 / 0.1...50 s in
increments of 0.1 s
(0 = delay time is not
active)
0 / 0.1...50 s in
increments of 0.1 s
(0 = delay time is not
active)