Les langues disponibles

Alternating current
Range
200.0 µA
2000 µA
20.00 mA
200.0 mA
2.000 A
10.00 A
Specified measured range: 5 - 100% of the measured range
Permissible display with a short-circuited measuring input: <2 counts
Frequency range 45 – 400 Hz; Overload protection 600 V;
Measuring converter AC-A: AC-coupled, real effective value (True RMS)
Additional tolerance at the following crest factor of the measuring signal:
CF 1.0 – 2.0
+3% for accuracy
CF 2.0 – 2.5
+5% for accuracy
CF 2.5 – 3.0
+7% for accuracy
Overload protection 600 V; high-performance ceramic fuses:
µA/mA-range F1: FF0, 2A H 600 V (6 x 32 mm)
A-range F2: F10A H 600 V (6 x 25 mm)
Resistance
Range
200.0 Ω*
2.000 kΩ
20.00 kΩ
200.0 kΩ
2.000 MΩ
20.00 MΩ
Overload protection 600 V PTC
Measuring voltage: max. 1 V
* Measuring accuracy after deduction of the line impedance of the measuring lines
Contact-free AC voltage recognition "NCV"
Range
220 V
Diode test
Test voltage
approx. 2.1 V
Overload protection: 600 V PTC; test current max. 1 mA
48
Accuracy
±(1,3% + 6)
±(1,5% + 8)
Accuracy
±(1,2% + 8)
±(1,5% + 6)
Frequency range
50 – 60 Hz
Resolution
0.001 V
Resolution
0.1 µA
1 µA
0.01 mA
0.1 mA
0.001 A
0.01 A
Resolution
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Display
Signal sound, not specified