Spare parts:
This machine requires no specific maintenance. The bearings are lubricated for life.
If work is required to replace wear parts such as the grindstones or the electrical or other
components, refer to the parts list (see exploded view at the end of the manual).
For all spare part orders (see references in the exploded view at the end of the manual), state:
• The machine type and serial number.
• The electrical specifications recorded under the machine.
This information is given on the identification plate (16) under the machine or
on the identification plate given on the last page of this manual.
Replacing the grindstones:
IMPORTANT: always change both the grindstones (9) at the same time.
The 2 grindstones are identical and can be fitted equally either on the moving plate (18)
(moving grindstone) or on the adjusting "nut" (5) (fixed grindstone) (fig. P and fig. Q).
1. Close the bean shutter (6) (fig. G).
2. Run the machine until the coffee beans waiting in the grinder body have passed through.
3. Stop the machine and unplug the mains power lead (10).
4. Take off the bean container (2).
5. With one hand, press the indexing pointer (7) and with the other unscrew the
adjustment nut (5), turning it in an anti-clockwise direction (fig. N).
Care: When fully unscrewed, handle this part with care so as not to damage the brass thread.
6. Unscrew the 3 screws (32) on each grindstone (fig. O and fig. Q). For the moving
grindstone, place a screwdriver across the grinder body and the coffee outlet tube to stop
the grindstone carrier plate from turning on unscrewing or tightening the grindstone
retaining screws.
7. Carefully clean the whole grinder body, in particular the grindstone facing areas.
8. Place each grindstone on its support making sure that there is no coffee dust between the
grindstone and its support.
9. Once both the grindstones have been replaced, with one hand press the indexing pointer
(7) and with the other place the ground coffee adjustment nut (5) onto the grinder body taking
care not to damage the thread. Without using force, put the nut (5) on the grinder body,
unscrewing it gently to feel for alignment of the two threads and thus to be able to feed them in
without using force. Then tighten until the 2 grindstones come into contact (fig. S).
10.Unscrew the "adjustment nut" (5) to free the grindstones in contact.
98160 06/2006
CARE: The slightest small coffee particle under the grindstone may prevent
the machine from operating correctly. It is recommended that the grinder
body is cleaned with a compressed air jet or a dry brush.
CARE: Do not unscrew the retaining shaft (17) from the grindstone carrier
plate (18) so as not to upset the geometry of the assembly (fig. P).