Measurement
Max. permissible standard deviation
inaccuracy
according to clinical testing:
Systolic 8 mmHg /
Diastolic 8 mmHg
Memory
4 x 30 memory spaces
Dimensions
L 134 mm x W 103 mm x H 60 mm
Weight
Approximately 367 g (without
batteries, with cuff)
Cuff size
22 to 36 cm
Permissible opera-
+10°C to +40°C, 10 to 85% relative humi-
ting conditions
dity (non-condensing)
Permissible storage
-20°C to +55°C, 10-90% relative humidi-
conditions
ty, 800-1050 hPa ambient pressure
Power supply
4 x 1.5 V
Battery life
For approx. 300 measurements, depen-
ding on levels of blood pressure and
pump pressure
Classification
Internal supply, IP21, no AP or APG,
continuous operation, application part
type BF
The serial number is located on the device or in the battery
compartment.
Technical information is subject to change without notification
to allow for updates.
• This device complies with European Standard
EN 60601-1-2 (In accordance with CISPR 11, IEC 61000-3-2,
IEC 61000-3-3, IEC 61000-4-2, IEC 61000-4-3,
All manuals and user guides at all-guides.com
AA batteries
IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6,
IEC 61000-4-7, IEC 61000-4-8, IEC 61000-4-11, EN 55024)
and is subject to particular precautions with regard to elec-
tromagnetic compatibility. Please note that portable and mo-
bile HF communication systems may interfere with this unit.
• The device complies with the EU Medical Devices Directive
93/42/EEC, the German Medical Devices Act (Medizin-
produkt gesetz) and the standards EN 1060-3 (Non-invasive
sphygmomanometers – Part 3: Supplementary requirements
for electro-mechanical blood pressure measuring systems)
and IEC 80601-2-30 (Medical electrical equipment – Part 2 –
30: Particular requirements for the basic safety and essential
performance of automated non-invasive sphygmomanom-
eters).
• The accuracy of this blood pressure monitor has been care-
fully checked and developed with regard to a long useful
life. If using the device for commercial medical purposes, it
must be regularly tested for accuracy by appropriate means.
Precise instructions for checking accuracy may be requested
from the service address.
13. Warranty / Service
Hans Dinslage GmbH, Riedlinger Straße 28, 89524 Uttenweiler,
Germany (hereinafter referred to as "HaDi") provides a warranty
for this product, subject to the requirements below and to the
extent described as follows.
The warranty conditions below shall not affect the seller's
statutory warranty obligations which ensue from the sales
agreement with the buyer.
31