Télécharger Imprimer la page

Lenz Digital plus LRB08 Information page 19

Détecteur à 8 sorties

Publicité

19
E
Change to the programming mode and select 'Programming a CV'.
The delay time can be set in the range 0.01 (10ms) to 2.55 seconds (2550ms) in
steps of 0.01 seconds (10ms).
The permissible value range is 1 to 255. It is possible that no feedback will come
from this input if value 0 is set.
If you want a specific delay time and you want to know the value that has to be
entered, calculate as follows:
x 100 =
Delay in seconds
Value for CV40
If you want to know which value corresponds to which delay time, calculate as
follows:
: 100 =
Value in CV40
Delay time in seconds
Ex-works, CV40 is set to 50 which corresponds to a delay time of 500ms.