FOR INSTALLERS AND PROFESSIONALS
country of the user, set up leakage protection devices (leakage operating current ≤30mA)
(12) The layout of power cable and signal cable should be orderly and not affecting each other;
considering the environmental condition (ambient temperature, direct sunlight, rain, power grid
voltage, cable length etc.)The cross-sectional area of the cable can be appropriately increased.
(13) Completed all the wiring, must be checked carefully then connect the power.
(14) If you use green energy to power this equipment, please make sure the power supply voltage is
stable and the voltage range is within the range indicated on the equipment. Unstable voltage
or voltage range beyond the indicated value will easily cause damage to the machine.
Electric wiring diagram
Power Supply
230V/50Hz
Model
Rated current (A)
Breaker
Rated residual Action
Current (mA)
Max input current (A)
Fuse (A)
Power cord (mm
Note: Above date is adapted to power cord ≤10m.If power cord ≥10m, wire diameter must be increased.
5.3. Trail after Installation
Please check all the wirings carefully before turning on the dehumidifier.
5.3.1. Inspection before use
(6) Check if the dehumidifier is vertically or horizontally placed on the ground or hung on the wall,
VARYUS 40
4.0
30
2.5
4.0
2
)
3x1.5
VARYUS 60
VARYUS 100
8.0
30
6.5
8.0
3x1.5
19
VARYUS 120
10.0
12.0
30
30
8.0
9.5
10.0
12.0
3x2.5
3x2.5