Press
Noticed wrong
boiler pressure.
Water
Boiler
temperature
Feeler
feeler signaling
Water
error.
Feeler
Exhaust feeler
signaling error
exhaust
Fume
Hot
temperature too
exhaust
high
Boiler water
Hot
temperature too
Water
high
A black-out has
happened during
Black-Out
the regular
working.
EXAMPLES OF APPLIANCE/PLANT CONNECTION
The following connection diagrams are only indications of some connection
possibilities and should not be considered as satisfaction in matter of installations.
Wrong pressure of thermal
plant.
Too high pressure
Electrical connections
interrupted.
Pressure switch control
breakdown.
Wrong appliance
carburation.
Change fuel.
Fume feeler
Wrong appliance
carburation
Breakdown/block
circulation plant pump.
Air inside the boiler.
Fume feeler.
72/116
IT IT IT IT- - - - GB
GB- - - - FR
FR mod. 698 TPC– 698 TP-SAC
GB
GB
FR
FR
Verify thermal plant pressure.
(min. 0,5bar max. 2bar).
Reduce the pressure of the plant by
draining water.
Verify the electrical connections of
pressure switch.
Verify/replace pressure switch
control.
Verify/replace temperature feeler.
Verify/replace exhaust feeler.
Verification of appliance by a
technical service center.
Proceed with "Pellet Correct".
Verification of appliance by a
technical service center.
Utilize better quality of pellet .
Proceed with "Pellet Correct".
Verify fume feeler position.
Verify/replace fume feeler.
Verification of appliance by a
technical service center.
Proceed with "Pellet Correct".
Verify circulation pump working
Eliminate air from the thermal plant
Verify boiler feeler position.
Verify/replace boiler feeler.
Empty and clean the burner basket
and then proceed with the lighting
phase.