EMERGENCY CONTROLBOARD PUSH BUTTONS FUNCTION
Button 3
- Switch ON and Switch Off.
Radio symbol
- Indicates the radio communication with the radiocontrol
Alarm symbol
- Indicates an alarm on the appliance.
Button 2
- Increases the working power of the appliance.
Button 1
- Reduces the working power of the appliance.
APPPLIANCE REGULATION
(to be completely carried out before effecting the 1st Lighting)
REGULATION of Heating water Temperature.
The appliance is provided with a thermostat put on the boiler for the control of the water
temperature sent to the plant, this thermostat reduces progressively the power of the appliance
(modulation) whenever the temperature of the water inside the boiler has reached the selected
temperature.
TO SELECT Water temperature (boiler)
-By mean of the radiocontrol, out of any menu press on button 6
-Regulate the temperature of plant utilizing the buttons 1 e 2
-Terminate the regulation of the temperature of the water pressing shortly on
button 6, the modification will be confirmed and the radiocontrol returns to
the previous indication
REGULATION of Sanitary water Temperature [not applicable for version 698TP-SAC]
The appliance is provided with a thermostat for the control of the temperature of sanitary
water, this thermostat regulates the power of the appliance in order to maintain the
temperature of the sanitary water whenever required, it is suggested to keep this temperature
higher by 10°C in respect of the temperature of the water for the heating plant.
The production of sanitary water occurs by mean of the use of a rapid exchanger, when warm
water is requested a feeler transfers this request to the appliance, which increases the power to
the max. level to satisfy the request and the power modulation will start as soon as the
selected value of sanitary water temperature has been reached.
TO SELECT Sanitary water temperature
-By mean of the radiocontrol, out of any menu press twice on button 6
-Regulate the temperature of the sanitary water utilizing the buttons 1 e 2
-Terminate the regulation of the temperature of the water pressing shortly on
button 6, the modification will be confirmed and the radiocontrol returns to
the previous indication